Specifications

Operating Zones NO RESTRICTIONS

Explorer will perform exactly according to spec
throughout the entire range.

Absolute Accuracy 0.1nT
Sensor Sensitivity 0.02nT RMS / rt-Hz
Counter Sensitivity 0.001nT
Resolution 0.001nT
Dead Zone NONE
Temperature Drift NONE
Power Consumption 2 W
Timebase stability 1ppm, -45°C to +60°C
Range 18,000nT to 120,000nT
Gradient Tolerance Over 10,000nT/m
Sampling Range 4Hz — 0.1Hz
Communications RS-232, 9600bps
Power Supply 9VDC – 40VDC or 100 – 240VAC
Operating Temperature -45°C to +60°C
Temperature Sensor -45°C to +60°C, 0.1 step

Towfish Dimensions

Towfish Length 86 cm (33.75 inches)
Towfish Diameter 6 cm (2.375 inches)
Towfish Weight in Air 3 kgs (7 lbs)
Towfish Weight in Water 1.2 kg (2.6 lbs)

Tow Cable

Conductors Four + shield
Strength Member Kevlar
Breaking Strength 2,500 kg (5,500 lbs)
Outer Diameter 1 cm (0.4 inches)
Bending Diameter 16.5 cm (6.5 inches)
Weight in Air 122 g/m 82 lb/1000 ft
Weight in Water 34 g/m 23 lb/1000 ft
Cable Termination Field Replaceable