Specifications

Operating Zones NO RESTRICTIONS

SeaSPY will perform exactly according to spec
throughout the entire range.

Absolute Accuracy 0.1nT
Sensor Sensitivity 0.01nT
Counter Sensitivity 0.001nT
Resolution 0.001nT
Dead Zone NONE
Heading Error NONE
Temperature Drift NONE
Power Consumption 1W standby, 3W maximum
Timebase stability 1ppm, -45°C to +60°C
Range 18,000nT to 120,000nT
Gradient Tolerance Over 10,000nT/m
Sampling Range 4Hz — 0.1Hz
External Trigger By RS-232
Communications RS-232, 9600bps
Power Supply 15VDC-35VDC or 100-240VAC
Operating Temperature -45°C to +60°C
Temperature Sensor -45°C to +60°C, 0.1 step

Flotation Cable

Conductors Twisted pair
Strength Member Vectran
Max Working Load 2,500 kg (5,500 lbs)
Outer Diameter 1.9 cm (0.74 inches)
Bending Diameter 25 cm (10 inches)
Weight in Air 125 g/m (0.84 lbs/ft)
Weight in Water -20 g/m (0.03 lbs/ft)
Outer Jacket Orange Polyurethane
Cable Termination Field Replaceable

Towfish

SeaSPY Towfish includes:

Towfish Length 124 cm (49 inches)
Towfish Diameter 12.7 cm (5 inches)
Towfish Weight in Air 16 kg (35 lbs)
Towfish Weight in Water 2 kg (4.4 lbs)

Tow Cable

Conductors Twisted pair
Strength Member Vectran
Breaking Strength 2,500 kg (5,500 lbs)
Outer Diameter 1 cm (0.4 inches)
Bending Diameter 16.5 cm (6.5 inches)
Weight in Air 125 g/m 84 lb/1000 ft
Weight in Water 44 g/m 29.5 lb/1000 ft
Outer Jacket Yellow Polyurethane
Cable Termination Field Replaceable

Battery Clip Cable or Power Supply

The power supply accepts any AC line power, from 100—240VAC and 50/60 Hz to provide conditioned and clean 24V DC power. Weight 165g (0.36lbs)